1. Equipment Spesification

  • Temperature sensor
    • Brand : SAAB MARINE ELECTRONICS
    • Type : PT 100
    • Position : 3 STBD Tank ,lower position
    • Range : -50ºC … 250 ºC
  • Transmitter Interface
    • Brand : SAAB MARINE ELECTRONICS
    • Type : 9150 064-632

2. Service Issue

In 3 STBD tank, temperature sensor for lower position is not function

3. Job Description

  • Check or calibration the temperature sensor to determine the condition of equipment.
  • Check termination and cable of temperature sensors termination in the junction box and transmitter interface.
  • Check the condition of the transmitter interface.
  • Check in I / O units.
  • Check in calculated program.
  • If found damage to the action taken to repair or replace a new

4. Documentation