Home » PPM sensors and alarm problem OWS RTE Smart Bilge

PPM sensors and alarm problem OWS RTE Smart Bilge

PPM sensors and alarm problem OWS RTE Smart Bilge

Specification Equipment:

  • Brand RTE
  • Type Smart Bilge 1 Unit
  • Product Rivertrace Engineering

Error Issue

  1. Ppm sensors does not detect correctly,
  2. Alarms do not function at 15 ppm (according to eligibility standards OWS)

Solution Resulting :

  • PPM Sensors
    • Need to do the calibration,
  • Alarm
    • Need to do setting parameter alarm 1 and 2, alarm delay 1 and 2.

Documentation

Smart Bilge Unit
Smart Bilge Unit
OWS Unit
OWS Unit