Home » Failed Alarm System Stern Thruster Kamome ASL Scorpio

Failed Alarm System Stern Thruster Kamome ASL Scorpio

Failed Alarm System Stern Thruster Kamome ASL Scorpio

Specification:

Equipment Stern Thruster

  • Brand Kamome
  • Serial T3242
  • Date 2009-3

Error Issue:

  • System Failed Alarm System Stern Thruster

Action Taken

  1. Checking the alarm section wiring.
  2. Checking lamp indicators,
  3. Checking contactor line is used for alarm. NO/NC

Solution Resulting:

  1. Cleaning all contactor which connected with the system failed.
  2. Repair wiring, as some line connected imperfect.
  3. There is no error in the system, only a mistake because some equipment / components do not connect properly current.

Documentation

Failed Alarm System Stern Thruster Kamome ASL Scorpio 1
Failed Alarm System Stern Thruster Kamome ASL Scorpio 1
Failed Alarm System Stern Thruster Kamome ASL Scorpio 2
Failed Alarm System Stern Thruster Kamome ASL Scorpio 2
Failed Alarm System Stern Thruster Kamome ASL Scorpio 3
Failed Alarm System Stern Thruster Kamome ASL Scorpio 3

Leave a Reply