Home » Check and Service Bilge System ASL Scorpio

Check and Service Bilge System ASL Scorpio

Check and Service Bilge System ASL Scorpio

Specification:

1. Bilge Control Monitor

  • Equipment Control Monitor
  • Brand ProFace

2. Level Switch

  • Equipment Level Switch
  • Brand Trimod Besta Level Switch
  • Type A 01 04
  • Power 250VAC/5A….30VDC/5A

Error Issue:

  1. Some level switchs do not work. Ie : no reaction when the water in bilge level change.
  2. Monitor shows some FAULT.
  3. Alarm are always active, can not reset.

Action Taken

  • Do the clean up on the component level switch,
    • 2 Nos level switchs is damage.
    • 3 Nos level switchs need repair.
    • 1 Nos level switchs must change of magnetic switch.
  • Setting the parameters on the control monitor for bilge system, because the setting have been messed up and change.
  • Caused by a fault in the control parameters, resulting in alarm command line contactor always comes out to alarm.

Solution Resulting:

  • Repairing 2 pieces level switch with damage is:
    • Level switch corroded,
    • Level switch broken.
  • Replacement of small parts on some level switch.
  • Setting parameters of bilge control monitor.

Documentation

Bilges System Controls Monitor
Bilges System Controls Monitor
Sensor Unit ( Level Switch)
Sensor Unit ( Level Switch)
Level Switch corroded
Level Switch corroded
Other type Level Switch
Other type Level Switch
Site
Site
Level Switch
Level Switch

Materi Job :

Leave a Reply