Repair and Calibration Fixed Gas Sampling System MT SG Bahari PT Samudera Gemilang Bahari

IDENTIFICATION RESULT Specification Name Device Fixed Gas Sampling System Control Unit Consillium Salwico SW2020 Analysing Unit Pump 107 CCD20 15 l/min, 230V 50/60 Hz Vacuum Guard VCM 095   Flow Meter Brooks 2700 0-300 l/h Detectors SIMRAD Optronics GD10 Filter/Pressure Reg. N1204-D00 0 – 4 kp/cm² Pressure Instrument M043 0 – 4 kp/cm² Filter N204-F00… Read More »Repair and Calibration Fixed Gas Sampling System MT SG Bahari PT Samudera Gemilang Bahari

Repair Steering Gear Port and STBD KT Bima I PT Seloko Batam Shipyard

IDENTIFICATION RESULT RESUL 1. Steering gear port and STBD systems cannot be commanded from the bridge. 2. Angular designation on the rudder Port and STBD is inconsistent SOLUTION AND ACTION TAKEN 1. Steering gear port and STBD systems cannot be commanded from the bridge.   Action   Result Solution Port STBD 1 Checking the signal cable between… Read More »Repair Steering Gear Port and STBD KT Bima I PT Seloko Batam Shipyard

MT Transko Bima Alarm and Monitoring Engine Room

MT Transko Bima Alarm and Monitoring Engine Room (2017) Job Engine room alarm and monitoring system could not detect the value of all the either sensor temperature, pressure and rpm meter is in the engine room. History This problem occurs when the installation of back up power ups for CPU monitoring engine room alarm system.… Read More »MT Transko Bima Alarm and Monitoring Engine Room

MT MTG 4 Aux Contactor Circulation Pump HTB Control Panel

MT MTG 4 Aux Contactor Circulation Pump HTB Control Panel (2015) Job Replace the contactor weak condition Fix the jumper jumper cables Job Detail Check the wiring and does the system work Check the performance of the contactor If found damaged then need to be replaced Test is the system Result This jumper cable is… Read More »MT MTG 4 Aux Contactor Circulation Pump HTB Control Panel

Patra Tanker 3 Rudder Not Functioning & Not Precision

Patra Tanker 3 Rudder Not Functioning & Not Precision (2016) Job 1. Repair Rudder Indicator in the Steering Room Cleanning module & indicator Check termination Measure resistance module & Rudder indicator Measure input power supply Calibrate indicator rouder 2. Rudder indicator Not terminated in the bridge space Check wiring from indicator indicator to module Measure… Read More »Patra Tanker 3 Rudder Not Functioning & Not Precision