Replace condenser cooling valve Provission Compressor

Replace condenser cooling valve Provission Compressor Equipment Spesification Globe valve Type : HA610 Size : 1 ¼ inch ( 4 pc ) Safety device Pressure switch Sea water : Danfoss , kp2 Pressure switch Discharge : Danfoss ,Kp 5 Pressure switch Suction : Danfoss ,Kp 5 Problems occurred Replace condenser cooling valve inlet & outlet… Read More »Replace condenser cooling valve Provission Compressor

Overhaull of Compressor Marine A/C 5H66-394

Overhaull of Compressor Marine A/C 5H66-394 Equipment Spesification Compressor Brand    :    Carlyle Model Number    :    5H66-394 Rpm motor    :    1470 Rpm Power motor    :    65.5 Hp Globe valve Type     :    10K Size    :    4 inch ( 3 pc ) Size    :    3 inch ( 2 pc ) Safety device Pressure switch Sea water    :   … Read More »Overhaull of Compressor Marine A/C 5H66-394

15 PPM Bilge Alarm BILGMON 488, The PPM alarm is not coming

15 PPM Bilge Alarm BILGMON 488, The PPM alarm is not coming Equipment Spesification 15 PPM Bilge Alarm  Brand    :    BILGMON Type    :    488 Power supply     :    115 VAC Check  results The PPM alarm is set at a point 15 ppm and time delay 000 second but our tests with 28 ppm alarm do… Read More »15 PPM Bilge Alarm BILGMON 488, The PPM alarm is not coming

Generator Starting System TAIYO Can not Starting From ECR

Generator Starting System TAIYO Can not Starting From ECR Specification: Engine Control System (ECS) Brand TAIYO Type – Voltage 24DCV Product by TAIYO Location ECR Error Issue: Starting condition generator: Can start of local control, Cant distart of ECR. Solution Resulting: Checking: 1. ECS (Engine Control System) ECS does not generate an output signal for… Read More »Generator Starting System TAIYO Can not Starting From ECR

Engine Monitor System MCU can’t Start Up and Language Problem NOR Control

Engine Monitor System MCU can’t Start Up and Language Problem NOR Control Specification: 1) Main Computer Unit 1(MCU 1) Brand NOR Control Type MCU8625 Voltage 115VAC Location ECR 2) Main Computer Unit 2(MCU 2) Brand NOR Control Type MCU8625 Voltage 115VAC Location ECR 3) Digital Governor Unit (DGU) Brand NOR Control Type DGU8800 Voltage 115VAC… Read More »Engine Monitor System MCU can’t Start Up and Language Problem NOR Control

Check System and Safety Hoist Crane Hong Nam S.W.L. 2 Ton

Check System and Safety Hoist Crane Hong Nam S.W.L. 2 Ton Specification: Equipment Hoist Crane Brand Hong Nam S.W.L. 2 Ton Product By Hong Nam Enterprise Co. LTD. Error Issue: 1. All devices need to be checked include: Checking of all electric motor. Checking of all slider. Remote. Wire. Electric Control 2. All Safety Device… Read More »Check System and Safety Hoist Crane Hong Nam S.W.L. 2 Ton

Check System and Safety Cargo Hoist Handling Hong Nam S.W.L. 10T

Check System and Safety Cargo Hoist Handling S.W.L. 10T Specification: Equipment Cargo Hoist Handling Crane Brand Hong Nam S.W.L. 10 Ton Working Radius 3.9 – 20 Meters Hoisting Speed 0 – 10 / 0 – 20 mm Sluffing Speed 99 Sec. Slewing Speed 0.8 RPM Class Cert. No. BUS000300S Hull No. N083 M.F.G. No. DN01-01-05… Read More »Check System and Safety Cargo Hoist Handling Hong Nam S.W.L. 10T

Check System and Safety Provision Crane Hong Nam S.W.L. 3 Ton

Check System and Safety Provision Crane Hong Nam S.W.L. 3 Ton Specification: Equipment Profision Crane Brand Hong Nam S.W.L. 3 Ton Product By Hong Nam Enterprise Co. LTD. Error Issue: 1. All devices need to be checked include: Hydraulic Pump and System. Hydraulic valve controller. Hydraulic handle for operator. All cylinders lifter. Hydraulic Swing. 2.… Read More »Check System and Safety Provision Crane Hong Nam S.W.L. 3 Ton

Fire alarm system experienced a fault in the addressable ELTEK EN54 by Honeywell

Fire alarm system experienced a fault in the addressable ELTEK EN54 by Honeywell 1. Equipment spesifikasi Fire detection panel Brand : ELTEK by Honeywell Type : Power supply : 220 VAC , battery 24VDC Alarm module Brand : ELTEK by Honeywell Type : EN54 Power supply : 220 VAC , battery 24VDC 2. Problems occurred… Read More »Fire alarm system experienced a fault in the addressable ELTEK EN54 by Honeywell