Repair and Calibration Oil Discharge Monitoring and Control System MT SG Bahari PT Samudera Gemilang Bahari

IDENTIFICATION RESULT Repair and Calibration Oil Discharge Monitoring and Control System Specification Name Device    : Oil Discharge Monitoring and Control System (ODMCS) MEPC 108(49) Computer Unit  : Cleantoil 2005 Pump Analize Unit Measuring Range : 0 – 1000 PPM Terminal Box : ATEX Cert, No. Sira 05ATEX2171 Measuring Unit : ATEX Cert, No. Sira 05ATEX2175 Flowmeter   … Read More »Repair and Calibration Oil Discharge Monitoring and Control System MT SG Bahari PT Samudera Gemilang Bahari

Check, Repair, Calibration and Certification Diaphragm Actuators Valve Nordic Bahari

Description Check , repair , calibration and certification of the Diaphragm Actuators Valve. for the Diaphragm Actuators Valve work is done in the workshop so the Diaphragm Actuators Valve  will be removed and under the workshop. Work performed Check and repair the diaphragm actuator unit Remove all parts and do cleaning. Check the condition of… Read More »Check, Repair, Calibration and Certification Diaphragm Actuators Valve Nordic Bahari

Repair and Calibration Fixed Gas Sampling System MT SG Bahari PT Samudera Gemilang Bahari

IDENTIFICATION RESULT Specification Name Device Fixed Gas Sampling System Control Unit Consillium Salwico SW2020 Analysing Unit Pump 107 CCD20 15 l/min, 230V 50/60 Hz Vacuum Guard VCM 095   Flow Meter Brooks 2700 0-300 l/h Detectors SIMRAD Optronics GD10 Filter/Pressure Reg. N1204-D00 0 – 4 kp/cm² Pressure Instrument M043 0 – 4 kp/cm² Filter N204-F00… Read More »Repair and Calibration Fixed Gas Sampling System MT SG Bahari PT Samudera Gemilang Bahari

Repair and Calibration OWS Oily Water Separator PT Karimun Marine Shipyard

IDENTIFICATION RESULT Specification Name Device WKODM-2 15PPM Oily Water Bilge Alarm Measurement range 0 ~ 30ppm (50ppm); Accuracy + 5ppm, meets IMO MEPC.107 (49) requirements Alarm points can be adjusted between 1 and 2 0 to 15ppm (the factory is set to 15ppm). Alarm point 1 (prompt alarm): Action lag time between 0 to 30… Read More »Repair and Calibration OWS Oily Water Separator PT Karimun Marine Shipyard

Repair Steering Gear Port and STBD KT Bima I PT Seloko Batam Shipyard

IDENTIFICATION RESULT RESUL 1. Steering gear port and STBD systems cannot be commanded from the bridge. 2. Angular designation on the rudder Port and STBD is inconsistent SOLUTION AND ACTION TAKEN 1. Steering gear port and STBD systems cannot be commanded from the bridge.   Action   Result Solution Port STBD 1 Checking the signal cable between… Read More »Repair Steering Gear Port and STBD KT Bima I PT Seloko Batam Shipyard

MT Transko Bima Alarm and Monitoring Engine Room

MT Transko Bima Alarm and Monitoring Engine Room (2017) Job Engine room alarm and monitoring system could not detect the value of all the either sensor temperature, pressure and rpm meter is in the engine room. History This problem occurs when the installation of back up power ups for CPU monitoring engine room alarm system.… Read More »MT Transko Bima Alarm and Monitoring Engine Room

MT MTG 4 Aux Contactor Circulation Pump HTB Control Panel

MT MTG 4 Aux Contactor Circulation Pump HTB Control Panel (2015) Job Replace the contactor weak condition Fix the jumper jumper cables Job Detail Check the wiring and does the system work Check the performance of the contactor If found damaged then need to be replaced Test is the system Result This jumper cable is… Read More »MT MTG 4 Aux Contactor Circulation Pump HTB Control Panel